Balwyn: taking the time to get it right

A large Balwyn home with more than ten hydronic panels, now completely off gas. We spent three to four months testing and modelling with the owners before choosing the heat pump, so it would actually keep the house warm.

HydroAir 22kW three phase hydronic heat pump with buffer tank, smart radiator heads, Rinnai Enviroflo AR 340L heat pump hot water

Where

Balwyn

What went in

HydroAir 22kW three phase hydronic heat pump with buffer tank, smart radiator heads, Rinnai Enviroflo AR 340L heat pump hot water

The outcome

Off gas, with a battery that can run the winter heating. No gas bills, and off the grid in peak hours.

Before

Balwyn: taking the time to get it right

After

HydroAir 22kW three phase hydronic heat pump with buffer tank, smart radiator heads, Rinnai Enviroflo AR 340L heat pump hot water

The home

This is a big home with more than ten hydronic panel radiators, heated by a gas boiler. Hot water came from a gas boosted solar storage tank.

The owners wanted off gas, but they did not want a cold house, or a system that cost more to run than they were told.

What we did

A home this size is where a hydronic heat pump can go wrong, so we did not rush it. Over three to four months we worked through it with the owners.

  • Turned the existing boiler down to lower water temperatures, to see how the house felt at the temperatures a heat pump runs at.
  • Modelled the running costs at realistic efficiency figures for a house with radiators, not the best case numbers on a spec sheet.
  • Fitted a buffer tank next to the heat pump. It stops the heat pump turning on and off too often, so it runs more steadily.
  • Fitted smart Bluetooth thermostatic heads on the radiators, so each room can be set and scheduled on its own.

In the end we settled on a HydroAir 22kW three phase hydronic heat pump, connected to the existing pipework and radiators.

For hot water, we replaced the gas boosted solar tank with a Rinnai Enviroflo AR 340 litre all in one heat pump. It is made in Australia, which also qualifies it for the higher Solar Victoria rebate for households that are eligible.

The result

The house is now completely off gas, with the gas capped at the meter.

Through winter, the home's 40kWh battery can run the heating on its own. The system is set up to keep the house off the grid in the expensive peak hours.

We set the heat pump's water temperature to 55°C. It runs for longer at a lower temperature than the old gas boiler did, which gives the house a steady, gentle warmth. And there are no big gas bills over winter.